When planning switchgear installations, it’s vital to consider the protection of the installers just as much as what’s installed. This protection requires tested and standardized structures and wise energy distribution.

Energy distribution in industrial plants and buildings often depends on the subsequent use in those structures. Standards are critical. That’s why a modular system consisting of standardized and tested products that meet the IEC 61 439 standard for low-voltage switchgear is so important.

IEC 61 439

The IEC 61 439 standard is a set of general rules on the assembly of low-voltage components. It clearly defines responsibility for compliance to switchgear and controlgear assembly standards, as well as the product liability of those involved. The standard has multiple expansions, including:

  • Part 1 applies to switchgear, power distribution boards, and control cabinets
  • Part 2 applies to the assembly of power switchgear and controlgear
  • Part 3 applies to distribution boards
  • Part 4 applies to construction site assembly
  • Part 5 applies to power distribution
  • Part 6 applies to busbar trunking systems


The five steps of project planning and construction

The project planning and construction of a user-specific distributor usually requires five key steps:

  1. 1. Definition or selection of influences, application conditions and interface parameters. The user should specify these parameters.
  2. 2. Draft of a distributor by the manufacturer so that the agreements, parameters, and functions applicable to that specific application are met. The distributor manufacturer must procure the design verifications for the parts used from the original manufacturer. If these are not available, the distributor manufacturer must provide the design verification.
  3. 3. The distributor is assembled with due regard for the documentation supplied by the device manufacturer/original manufacturer of the system.
  4. 4. A routine verification must be conducted by the manufacturer for each distributor.
  5. 5. The conformity assessment procedure should be carried out. Compliance with the relevant legislation – in this case, in particular, the Product Safety Act (ProdSG) and the EMC Act – and the associated Declaration of Conformity including CE labelling pre-suppose application of the IEC 61 439 series of standards.

Important_Links_Bar.jpg

https://blog.rittal.us/the-5-steps-for-safe-switchgear-installation-within-enclosures

 

Related Articles

Network Infrastructure Featured Product Spotlight

PBUS 14 Panduit logo 400

This webinar presented by Beth Lessard and Keith Cordero will be highlighting three Panduit solutions that will optimize network equipment and cabling to ensure that your spaces are efficiently and properly managed to support ever-evolving business needs of today and beyond. Products that will be featured include PanZone TrueEdge Wall Mount Enclsoure, Cable Managers, and Adjustable Depth 4-Post Rack.

REGISTER HERE


Editor’s Pick: Featured Product News

Siemens: SIMOVAC Non-Arc-Resistant and SIMOVAC-AR Arc-Resistant Motor Controllers

The Siemens SIMOVAC medium-voltage non-arc-resistant and SIMOVAC-AR arc-resistant controllers have a modular design incorporating up to two 12SVC400 (400 A) controllers, housed in a freestanding sheet steel enclosure. Each controller is UL 347 class E2, equipped with three current-limiting fuses, a non-load-break isolating switch, and a fixed-mounted vacuum contactor (plug-in type optional for 12SVC400). The enclosure is designed for front access, allowing the equipment to be located with the rear of the equipment close to a non-combustible wall.

Read More


Sponsored Content
Electrify Your Enterprise

Power is vital to production, and well-designed control cabinets are key. Allied Electronics & Automation offers a comprehensive collection of control cabinet solutions including PLCs, HMIs, contactors, miniature circuit breakers, terminal block connectors, DIN-rail power supplies, pushbutton switches, motor starters, overloads, power relays, industrial Ethernet switches and AC drives engineered to keep your operations running safely, reliably and efficiently.

Learn more HERE.


Products for Panel Builders

  • Omron: S8NR IP67 Power Supply

    Omron: S8NR IP67 Power Supply

    The OMRON S8NR Series is an IP67 rated industrial power supply designed for out of panel installation in harsh environments where dust, moisture, vibration, and accessibility challenges impact reliability. By moving the power supply outside the control panel, S8NR reduces enclosure complexity, electrical labor, and service time while maintaining stable, protected DC power delivery. Read More…

  • Altech Corp.: 85-A STH5 Hinge-Type Terminal Blocks Resist Vibrations and Provide Fast, Safe Access

    Altech Corp.: 85-A STH5 Hinge-Type Terminal Blocks Resist Vibrations and Provide Fast, Safe Access

    In power distribution, heavy-duty machinery and transportation applications, vibrations can weaken a terminal block’s clamping power and loosen wire connections. The resulting power and signal failures can lead to unwanted system downtime, fire and shock risks, or other safety issues. Fortunately, one type of terminal block design makes secure connections possible while also providing easy… Read More…